Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Odovtos (En línea) ; 25(3): 82-98, Sep.-Dec. 2023. tab, graf
Article in English | LILACS, SaludCR | ID: biblio-1529071

ABSTRACT

Abstract To evaluate the microtensile bond strength (µTBS) of two resin cements to 3D printed and milled CAD/CAM resins used for provisional fixed partial dentures. Blocks (5 x 5 x 5 mm) of three 3D-printed resins (Cosmos3DTemp / Yller; Resilab3D Temp / Wilcos and SmartPrint BioTemp, / MMTech) were printed (Photon, Anycubic Technology Co.). A milled material (VitaCAD-Temp, VITA) was used as control. Half the specimens were sandblasted and the rest were untreated. Two blocks were bonded with the corresponding resin cement: PanaviaV5 (Kuraray Noritake) and RelyX Ultimate (3M Oral Care). After 24 hours, the bonded blocks were sectioned into 1 x 1 mm side sticks. Half the beams were tested for µTBS and the other half was thermocycled (5000 cycles, 30s dwell-time, 5s transfer time) before µTBS testing. A four way Generalized Linear Model (material*sandblasting*cement*aging) analysis was applied. VITA exhibited the lowest µTBS, regardless of the cement, sandblasting and thermocycling. Sandblasting significantly improved the µTBS of VIT, especially after aging, but did not improve the µTBS of 3D printed resins. Sandblasting was not beneficial for 3D printed resins, although is crucial for adhesive cementation of milled temporary resins. Airborne particle abrasion affects the integrity of 3D-printed resins, without producing a benefit on the microtensile bond strength of these materials. However, sandblasting is crucial to achieve a high bond strength on milled temporary resins.


Resumen Evaluar la resistencia adhesiva en microtracción (µTBS) de dos cementos resinosos a resinas CAD/CAM impresas y fresadas indicadas para restauraciones provisionales. Bloques (5 x 5 x 5mm) de tres resinas impresas (Cosmos3DTemp / Yller; Resilab3D Temp / Wilcos and SmartPrint BioTemp, / MMTech) y una resina fresada (VitaCAD-Temp, VITA) fueron fabricados. La mitad de los especímenes fueron arenados y el resto no recibió tratamiento mecánico. Dos bloques con condiciones de tratamiento iguales fueron cementados con cemento resinoso (PanaviaV5 / Kuraray Noritake y RelyX Ultimate / 3M Oral Care). Después de 24 horas los bloques fueron seccionados en palitos de 1 mm² de área. En la mitad de los especímenes se midió la TBS inmediatamente y el resto fue termociclado (5000 ciclos, 30s remojo, 5s transferencia) antes de la prueba de TBS. Se aplica un análisis estadístico por Modelo Linear General con 4 factores (material*arenado*cemento*termociclado). La resina VITA presentó la menor µTBS, independientemente del cemento usado, el arenado y el termociclado. Sin embargo, el arenado aumentó la µTBS de VIT, especialmente después del termociclado. Por otro lado, el arenado no resultó en un aumento significativo de la µTBS de las resinas impresas. El arenado no fue beneficiosos para las resinas impresas, aunque es un paso crucial para la cementación adhesive de las resinas fresadas. El arenado afecta la integridad de las capas de las resinas impresas, sin generar un beneficio en la TBS.


Subject(s)
Computer-Aided Design/instrumentation , Resin Cements/therapeutic use , Dental Cementum , Printing, Three-Dimensional/instrumentation
2.
Rev. cient. odontol ; 8(2): e015, mayo-ago. 2020. ilus, tab
Article in Spanish | LILACS, LIPECS | ID: biblio-1118804

ABSTRACT

Objetivo: Comparar la resistencia de unión a la dentina del cemento sellador tipo Grossman (Grossdent) y Apexit Plus (Ivoclar Vivadent) después de la medicación intraconducto de hidróxido de calcio Ca(OH)2 con vehículos de paramonoclorofenol alcanforado (PMCFA) y de clorhexidina al 2% (CHX). Metodología: Estudio experimental in vitro. Se seleccionó una muestra de 44 dientes humanos monorradiculares y fueron divididos en 4 grupos con medicación intraconducto (n = 9) y 2 grupos control. Los dientes fueron desinfectados y los conductos radiculares instrumentados usando una técnica híbrida. Se medicaron dos grupos con hidróxido de calcio más PMCFA y dos grupos con hidróxido de calcio más CHX 2% durante dos semanas. De cada grupo con medicación uno fue obturado con cemento sellador endodóntico Grossman y el otro con Apexit Plus, mediante la técnica de compactación lateral. Los grupos control fueron obturados solo con los dos cementos anteriormente mencionados. Se cortaron las muestras en discos de 2 mm de espesor y fueron sometidas a prueba de empuje con una máquina de ensayo universal. Resultados: El valor de la media más alta lo obtuvo el grupo medicado con Ca(OH)2 más PMCFA y obturado con Apexit Plus (m 3,742 y DE 0,808), mientras que el valor más bajo lo presentó el grupo de Ca(OH)2 más PMCFA obturado con cemento Grossman (m 1,371 y DE 0,699), presentaron diferencias significativas (p < 0,001). Conclusión: La resistencia de unión a la dentina radicular se ve influenciada por la medicación intraconducto previa a la obturación endodóntica. (AU)


Objective: Compare the dentin bond strength of Grossman ́s sealer (Grossdent) and Apexit Plus sealer (IvoclarVivadent) after intra-canal medication of calcium hydroxide Ca(OH)2 associated with vehicles of camphorated parachlorophenol (CMPC) and chlorhexidine 2% (CHX). Methodology: This was an in vitro experimental study. A sample of 44 monoradicular human teeth were disinfected and divided into 4 groups of intra-canal medication (N= 9) and 2 control groups. The teeth were disinfected and root canals were instrumented using a hybrid technique. Two groups were medicated with Ca(OH)2 and CMPC and two groups with Ca(OH)2 and CHX 2% for two weeks. One group of each medication was filled with Grossman ́s sealer and the others with Apexit Plus sealer using the lateral compaction technique. The control groups were filled only with the two sealers mentioned previously. Samples were cut into 2 mm thick discs and placed on a push test with a universal testing machine. Results: The highest value of the means was obtained by the group medicated with Ca(OH)2 in association with CMPC and filled with Apexit Plus (m 3.742; SD 0.808), while the lowest value was presented by the group of Ca(OH)2 associated with CMPC, filled with Grossman ́s sealer (m 1,371; SD 0.699). Statistical differences were considered with p<0.001. Conclusion: Root dentin bond strength is influenced by intra-canal medication prior to endodontic filling. (AU)


Subject(s)
Humans , Pit and Fissure Sealants , Root Canal Therapy , Calcium Hydroxide/therapeutic use , Endodontics
3.
Rev. cient. odontol ; 6(1): 72-83, ene.-jun. 2018. ilus., tabs., grafs.
Article in Spanish | LILACS | ID: biblio-998842

ABSTRACT

Objetivo: Comparar la resistencia a la microtensión entre dentina y resina de laboratorio Ceramage (Shofu) microa- renada, con óxido de aluminio de 25, 50 y 90 micrómetros, y un grupo sin microarenado. Materiales y métodos: Se utilizaron 12 terceros molares sanos, 3 por cada grupo. Se cortó la super- ficie de esmalte oclusal con un disco diamantado biactivo (BesQual) de 22 mm para exponer una superficie plana de dentina. Se fabricaron 12 bloques de resina de laboratorio Ceramage (Shofu) en un molde cilíndrico de teflón con un diámetro de 8 mm y una altura de 4 mm. Se tuvieron 4 grupos de estudio (3 bloques por grupo), a los que aleatoria- mente se aplicaron los siguientes trata- mientos de superficie: G1, sin microa- renar (grupo control); G2, con Al2O3 de 25 µm (Zhermack); G3, con Al2O3 de 50 µm (Bioart), y G4, con Al2O3 de 90 µm (Bioart). La cementación de los bloques a la dentina se realizó con el cemento resinoso autoadhesivo Maxcem Elite (Kerr). Se obtuvieron especímenes de aproximadamente 1 mm2 de área transversal (n = 26 especímenes por grupo) con una máquina de corte tipo IsoMet y se almacenaron en agua desti- lada por 24 horas a 37 °C. La prueba de microtensión se realizó haciendo uso de un microtensiómetro (Microtensile Tester - Bisco). Para el análisis estadís- tico se utilizaron las pruebas de Anova y Tukey, donde p < 0,001. Resultados: Los valores de la media y de la desviación estándar, para la variable resistencia a la microtensión de cada grupo, fueron las siguientes: para el G1 sin microarenado, 7,03 (± 2,94) Mpa; para el G2, microare- nado con 25 µm: 4,63 (± 1,28) Mpa; para el G3, microarenado con 50 µm: 4,56 (± 1,40) Mpa; y para el G4, microarenado con 90 µm: 5,93 (± 1,39) Mpa. Conclu- sión: La resistencia de unión entre el grupo que no recibió ningún tratamiento de superficie y el que empleó partículas de 90 µm es similar, razón por la cual se podría prescindir del microarenado como tratamiento de superficie. Además, la resistencia de unión del grupo que empleó partículas de 90 µm es superior a los grupos que emplearon 25 y 50 µm. (AU)


Objective: To compare the micro-tensile bond strength of dentine and the labora-tory composite "Ceramage" (Shofu), sand-blasted with 25, 50 and 90 micrometer aluminum oxide, and a control group not subjected to sandblasting. Materials and methods: 12 third molars were used, 3 in each group. The surface of the occlusal enamel was cut with a 22 mm bioac-tive diamond disc (BesQual), exposing a flat surface of dentin. 12 blocks of the laboratory composite Ceramage (Shofu) were manufactured in a cylin-drical Teflon mold with a diameter of 8 mm and a height of 4 mm. There were 4 study groups (3 blocks per group), upon which the following surface treatments were randomly performed: (g1): without sandblasting (c ontrol group); (g2): with 25 µm al2o3 (zhermack); (g3): with 50 µm al2o3 (bioart) and (g4): with 90 µm Al2O3 (Bioart). The cementation was made using Maxcem elite (Kerr) self-adhesive resin cement. Specimens of approximately 1 mm2 in cross-sectional area (n=26 specimens by group) were obtained using an IsoMet type cutting machine and stored in distilled water for 24 hours at 37°C. The micro-tensile test was performed using a Micro-tensile tester machine (Bisco). The Anova and Tukey tests were applied to the statis-tical analysis (p <0.001). Results: The mean and standard deviation values for the micro-tensile bond strength of each group were as follows: f or group 1 (g1) without sandblasting: 7.03 (+ 2.94) Mpa; for group 2 (G2) sandblasted with 25 µm: 4.63 (+ 1.28) Mpa; for group 3 (g3) sandblasted with 50 µm: 4.56 (+ 1.40) Mpa; and for group 4 (G4) sandblasted with 90 µm: 5.93 (+ 1.39) Mpa. Conclu-sions: The micro-tensile bond strength of the group which did not receive any surface treatment and the group subjected to 90 µm particles is similar, indicating that sandblasting could be dispensed with as a surface treatment. Also, the micro-tensile bond strength of the group subjected to 90 µm particles is superior to that of the groups subjected to 25 and 50 µm. (AU)


Subject(s)
Resin Cements , Dentin , Aluminum Oxide , Polymerization
4.
Odovtos (En línea) ; 19(2)ago. 2017.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1506904

ABSTRACT

ctualmente existe controversia en la literatura acerca de la efectividad clínica y adhesiva con respecto a los sistemas adhesivos de refuerzo radicular. Así, el objetivo de este estudio fue evaluar la resistencia de unión mediante la prueba de Push-Out entre el sistema de postes Rebilda® y la dentina intraradicular. Para esto, se utilizaron 28 dientes unirradiculares, que fueron cortados y padronizados en 16 mm. Los segmentos radiculares fueron sometidos a confección de tratamiento endodóntico; posteriormente, se dividieron aleatoriamente en dos grupos, Grupo 1 (n=14): Rebilda® DC+Futurabond DC; Grupo 2 (n=14): RelyX ARC+Adper Scothbond Multipropósito Plus. Seguidamente, diez especímenes de cada grupo se cortaron para ser sometidos al Test de Push-Out. Los restantes 4 especímenes de cada grupo se prepararon para Microscopia Electronica de Barrido con el fin de evaluar la formación de prolongaciones resinosas en la interface poste-cemento-dentina. El grupo 2 obtuvo mejores resultados al compararlo al Grupo 1 en cuanto a resistencia de unión y en formación de prolongaciones resinosas, pero no hubo diferencia estadísticamente significativa (p>0.05). Se concluyó que el Sistema de Postes REBILDA® promueve una adecuada resistencia de unión a dentina intrarradicular.


urrently there is controversy in the literature about clinical and adhesive effectiveness with respect to adhesive systems aimed to root reinforcement. Thus, the objective of this study was to evaluate the Push-Out bond strength between the Rebilda® post system and the intraradicular dentine. Thus, 28 unirradicular teeth were used, cut and standardized in 16 mm. The root segments were submitted to endodontic treatment; and then randomly divided into two groups, Group 1 (n = 14): Rebilda® DC + Futurabond DC; Group 2 (n = 14): RelyX ARC + Adper Scothbond Multipurpose Plus. Ten specimens from each group were submitted to the Push-Out Test. The remaining 4 specimens from each group were prepared for Scanning Electron Microscopy (SEM) in order to evaluate the formation of resinous extensions at the post-cement-dentin interface. Group 2 showed better results when compared to Group 1 regarding bond strength and in formation of resinous extensions or tags, but there was no statistically significant difference (p>0.05). It was concluded that the REBILDA® Post System promotes adequate bond strength to intraradicular dentin.

5.
Rev. cient. odontol ; 4(1): 409-417, ene.-jun. 2016. tab, graf
Article in Spanish | LILACS, LIPECS | ID: biblio-999753

ABSTRACT

OBJETIVO: Comparar el efecto de los diferentes tiempos de grabado ácido (0, 10, 20 y 30 segundos) sobre la resistencia unión de un sistema adhesivo autoacondicionante en esmalte bovino. MATERIALES Y MÉTODO: Este estudio fue experimental, in vitro. Se utilizaron 8 dientes bovinos, distribuidos aleatoria-mente, de los cuales se obtuvieron 120 especímenes; que fueron divididos en 4 grupos (n=30); según los diferentes tiempos de grabado ácido al 37 % (Scotchbond-3M Espe); un grupo control (G1: sin grabado ácido.) y tres grupos experimentales (G2: 10, G3: 20 y G4: 30 segundos) haciendo uso de un sistema adhesivo autoacondicionante (All-Bond Universal. Bisco). Se aplicó la prueba de microtensión a todos los especímenes obtenidos a una velocidad de 1.0 mm/min. Se realizó un análisis univariado, luego un análisis bivariado ANOVA One-Way, y por último la prueba Post Hoc de HSD de Tukey. El intervalo de confianza fue de 95 % y el criterio de significancia p< 0.05.RESULTADOS: Los promedios de la resistencia de unión de los 4 grupos de diferentes tiempos de grabado ácido fueron: Grupo 1: 16.81 MPa (DE ± 4.95), Grupo 2: 26.23 MPa (DE ± 5.60), Grupo 3: 25.29 MPa (DE ± 7.43) y Grupo 4: 20.19 MPa (DE ± 3.55), se encontró entre estos promedios diferencias estadísticamente significativas p<0.001. Se hicieron comparaciones por grupos usando el análisis bivariado ANOVA One-Way y Post Hoc de HSD de Tukey, con los siguientes resultados: Al comparar los grupos 1 y 2 (0 seg. ­ 10 seg.); el valor p=0.000, el grupo 1 y 3 (0 seg. - 20 seg.); el valor p=0.000 y los grupos 2 y 4 (10 seg. ­ 30 seg. ); el valor p=0.000. CONCLUSIÓN: Existen diferencias estadísticamente significativas al comparar los diferentes tiempos de grabado ácido (grupo control y los 3 grupos experimentales) sobre la resistencia de unión de un sistema adhesivo autoacondicionante en esmalte bovino. El Grupo 2 presentó una mayor resistencia de unión. (AU)


OBJECTIVE: To compare the effect of different acid etching times (0, 10, 20 and 30 seconds) on the bond strength of a self-etching adhesive system in bovine enamel. MATERIALS AND METHODS: This study was experimental, in-vitro. Eight bovine teeth were used, randomized, of which 120 specimens were obtained; they were divided into 4 groups (n=30); according to the different acid etching times at 37 % (Scotch-bond-3M Espe); control group (G1: without acid etching) and three experimental groups (G2:10, G3: 20 and G4: 30 seconds) using a self-etching adhesive system (All-Bond Universal. Bisco). A microtensile test was applied to all the specimens obtained at a speed of 1.0 mm/min. Univariate analysis was performed, then a bivariate analysis One-Way ANOVA and finally Tukey ́s HSD Post Hoc test. The confidence interval was 95% and the significance criteria was p<0,05.RESULTS: The average of bond strength of the 4 groups of different acid etching times evaluated were: Group 1: 16.81 MPa (SD ± 4.95), Group 2: 26.23 MPa (SD ± 5.60), Group 3: 25.29 MPa (SD ± 7.43) and Group 4: 20.19 MPa (SD ± 3.55). It was found among these averages statistically significant differences p<0.001. Comparisons were made by groups using bivariate analysis One-Way ANOVA and Tukey's HSD Post-Hoc, with the following results: When comparing groups 1 and 2 (0 sec.- 10 sec); p-value=0.000, groups 1 and 3 (0 sec. - 20 sec); p-value=0.000 and groups 2 and 4 (10 sec. - 30 sec.); p-value=0.000.CONCLUSION: There were statistically significant differences when comparing different acid etching times (control group and the three experimental groups) on the bond strength of a self-etching adhesive system in bovine enamel. Group 2 had a higher bond strength. (AU)


Subject(s)
Animals , Cattle , Acid Etching, Dental , Dental Cements , Dental Enamel , Materials Science
6.
Article in Spanish | LILACS | ID: lil-660040

ABSTRACT

Introducción: Los procedimientos restauradores indirectos son comunes en la clínica diaria actual. Se debe tener cuidado especial en la cementación, pues la gran mayoría de los fracasos ocurren en la interfase diente/restauración. Por esto es indispensable un adecuado tratamiento de superficie de la restauración para lograr una adhesión óptima a la superficie dentaria. Materiales y Métodos: Treinta cilindros de porcelana VITA VM 13 con dimensiones de 5 mm de altura y 7 mm de diámetro fueron separadas aleatoriamente en 3 grupos (n=10) de acuerdo con los tratamientos recibidos. Grupo I (control) - sin acondicionamiento superficial; Grupo II - grabado con ácido fluorhídrico al 9.6 por ciento por 1 minuto; Grupo III - grabado con ácido fluorhídrico al 9.6 por ciento por 2 minutos. Estas fueron probadas en cuanto a su resistencia de unión a la tracción en una máquina universal para pruebas (INSTRON modelo 4411, 3M). Los valores, expresados en MPa, fueron analizados estadísticamente a un nivel de significación del 5 por ciento, usando el Análisis de la Varianza (ANOVA) de un factor. Resultados: En relación con la prueba de resistencia de unión a la tracción, se encontraron los siguientes valores medios para cada grupo: Grupo I (control) - x=3.35 MPa; Grupo II - x=4.64 MPa; Grupo III - x=3.80 MPa. Conclusiones: Según los resultados obtenidos, se puede concluir que el tratamiento de superficie con ácido fluorhídrico durante 1 minuto, promueve microrretenciones que aumentan significativamente los valores de resistencia a la tracción, que puede traducirse en un beneficio clínico mayor.


Aim: Indirect restorative procedures are common in the current daily practice. Special care must be taken in the cement, as the vast majority of failures occurs at the interface tooth /restoration. Therefore a proper surface treatment of the restoration is essential to achieve optimum adhesion to the tooth surface. Materials and Methods: Thirty porcelain cylinders VITA VM 13 with dimensions of 5 mm in height and 7 mm in diameter were randomly divided into 3 groups (n=10) according to the treatments received. Group I (control) - no surface conditioning; Group II- recorded with 9.6 percent hydrofluoric acid for 1 minute; Group III - recorded with 9.6 percent hydrofluoric acid for 2 minutes. Their tensile bond strength was tested in a universal testing machine (Instron Model 4411, 3M). The values, expressed in MPa, were statistically analyzed at a level of significance of 5 percent, using Analysis of Variance (ANOVA) of a factor. Results: In relation to the bond strength test, tensile strength, revealed the following values for each group: Group I (control) - x=3.35 MPa, Group II - x=4.64 MPa, Group III - x=3.80 MPa. Conclusions: According to the results, it can be concluded that the surface treatment with hydrofluoric acid for 1 minute promotes microretentions, which significantly increase the values of bond strength, tensile strength. This can result in a higher clinical benefit.


Subject(s)
Hydrofluoric Acid/chemistry , Acid Etching, Dental/methods , Dental Porcelain/chemistry , Analysis of Variance , Ceramics , Composite Resins , Dental Bonding , Materials Testing , Stress, Mechanical , Surface Properties , Time Factors
7.
Acta odontol. venez ; 49(1)2011. tab, graf
Article in Spanish | LILACS | ID: lil-678859

ABSTRACT

El objetivo de este trabajo "in vitro" fue evaluar la resistencia de unión de dos sistemas adhesivos utilizando el ensayo de microtracción, variando el tipo de substrato dentinario. Fueron utilizados 32 terceros molares humanos recientemente extraídos, los cuales fueron divididos en cuatro grupos de acuerdo con la orientación de los túbulos dentinarios (paralelos o perpendiculares) y con el tipo de sistema adhesivo utilizado (convencional o auto-acondicionante). Además de evaluar la resistencia de unión, todas las muestras fueron examinadas visualmente para determinar el tipo de fractura. Posteriormente, los resultados fueron sometidos a análisis estadística, permitiendo concluir que los adhesivos autoacondicionantes poseen un mejor comportamiento, mostrando mayor resistencia de unión a la dentina cuando los túbulos dentinarios están expuestos paralelamente al largo del eje del elemento dentario. Sin embargo cuando los túbulos dentinarios están perpendiculares al eje del diente, los sistemas adhesivos convencional y autoacondicionantes poseen resistencia adhesiva semejante. En cuanto al tipo de fractura de los cuerpos de prueba, las fallas adhesivas son predominantes, independiente del sistema adhesivo utilizado y del tipo de substrato dental


The aim of this in vitro study was to evaluate the microtensile bond strength, for two adhesive systems, varying the dentin substrate. Thirty-two recently extracted third molars human were used, and divided in four groups according to the dentin tubules orientation (parallels and perpendiculars) and the adhesive systems (total-etching and self-etching). The specimens were examined by optical microscope for determined the fracture type. After, the statistical analysis was evaluated, allowing to conclude that the self-etching adhesive systems showed better behavior and greater bond strength for dental substrate, when the dentin tubules were parallel exposited to dental axis. Nevertheless, when the dentin tubules were perpendiculars, the total-etching and self-etching adhesive systems showed similar statistical bond strength values. For the fracture type of the specimens, adhesive fractures were predominant, independent of the adhesive systems and the type of dental substrate used


Subject(s)
Dental Cements , Dental Materials , In Vitro Techniques , Metal Ceramic Alloys
SELECTION OF CITATIONS
SEARCH DETAIL